Draping Checklist

Draping

Draping Materials

  • 6 strips ioban
    • 2 for CK sleeves (3 fingers width)
    • 4 for securing towels
  • 7 blue towels
    • 4 towels for draping
    • 3 for suctions
  • Blue abdominal drape
  • ¾ sheet x 2
  • Pocket drape (3M 6658)
  • C-armor
  • C-Arm Showercap
  • Suction x 4
    • 1 in C-armor
    • 2 in pouch drape
    • 1 for bumper
  • Instrument pouch x1 (1018)
  • Irrigation tubing (cysto tubing)
  • 8 Allis clamps
  • Light cord to say "ND" (extra long)
  • Stryker camera (384 is #1, cleaned)
  • L2-3 or higher: need >2 needles for counting-18 gauge
  • Draping Steps

  • Start with down sheet, 1 cm below the 10x10
  • Start with bottom blue towel – one 1 cm cranial to down sheet
  • Top blue towel
  • Lateral blue towel on opposite side first with 4 cm ioban, bring extra ioban down onto down drape
  • Other lateral blue towel with 4 cm ioban on surgery side, use extra ioban for down drape
  • Lap drape with circumferential pockets for irrigation – go slightly lateral to surgery side to allow for TF approach, if also IL make sure you can still see the midline
  • C-arm cover - opposite side of C-arm
  • Throw off suctions towards suction machine - will have three with tips cut off and clamps
    • Measure suctions by putting into most south part of drape so X-ray does not see, clamp to towel, ensure suction holes are not covered
  • Cut 2 small holes in cranial part of pocket drape to feed suctions on each side through, C-armor suction does not go through hole
  • One suction in C-armor, one in each side of pocket drape (3 total)
  • Pocket for Triggerflex on opposite side of surgeon on patient’s shoulder blade
  • Secure suctions with right white Velcro
  • Secure Triggerflex +/- drill with left Velcro
    • Measure Triggerflex and drill by putting ends into south white Velcro/on Mayo stand
  • Assembling drill
    • Lubricate drill bit with mineral oil
    • Put handpiece in open position
    • Connect handpiece to motor
    • Twist handpiece until it locks into place
    • Insert drill bit
    • Twist handpiece to closed position
    • Twist support tube to lock down
    • Press foot pedal slowly to test drill
  • Attach light cord
  • Attach stopcock to southmost outflow of scope
  • Attach irrigation to stopcock
  • Scope condom for TF
    • Cut a small hole in the top of the condom and put on base - this should go to about 1 inch past connection for the black cord
  • White balance camera (Hold W) and make sure zoom is good, check quality
  • Make sure laser on field with towel over cord
  • Last special clamp on Mayo
  • C-arm shower cap
  • If retractor: put on retractor clamp onto clamp on bed
    • Arm of retractor should have flat face facing out
    • Angle second arm 45 degrees