LESS Master Checklist Home > Draping
Draping
Draping Materials
-
6 strips ioban
- 2 for CK sleeves (3 fingers width)
- 4 for securing towels
-
7 blue towels
- 4 towels for draping
- 3 for suctions
- Blue abdominal drape
- ¾ sheet x 2
- Pocket drape (3M 6658)
- C-armor
- C-Arm Showercap
-
Suction x 4
- 1 in C-armor
- 2 in pouch drape
- 1 for bumper
- Instrument pouch x1 (1018)
- Irrigation tubing (cysto tubing)
- 8 Allis clamps
- Light cord to say "ND" (extra long)
- Stryker camera (384 is #1, cleaned)
- L2-3 or higher: need >2 needles for counting-18 gauge
- Start with down sheet, 1 cm below the 10x10
- Start with bottom blue towel – one 1 cm cranial to down sheet
- Top blue towel
- Lateral blue towel on opposite side first with 4 cm ioban, bring extra ioban down onto down drape
- Other lateral blue towel with 4 cm ioban on surgery side, use extra ioban for down drape
- Lap drape with circumferential pockets for irrigation – go slightly lateral to surgery side to allow for TF approach, if also IL make sure you can still see the midline
- C-arm cover - opposite side of C-arm
-
Throw off suctions towards suction machine - will have three with tips cut off and clamps
- Measure suctions by putting into most south part of drape so X-ray does not see, clamp to towel, ensure suction holes are not covered
- Cut 2 small holes in cranial part of pocket drape to feed suctions on each side through, C-armor suction does not go through hole
- One suction in C-armor, one in each side of pocket drape (3 total)
- Pocket for Triggerflex on opposite side of surgeon on patient’s shoulder blade
- Secure suctions with right white Velcro
-
Secure Triggerflex +/- drill with left Velcro
- Measure Triggerflex and drill by putting ends into south white Velcro/on Mayo stand
-
Assembling drill
- Lubricate drill bit with mineral oil
- Put handpiece in open position
- Connect handpiece to motor
- Twist handpiece until it locks into place
- Insert drill bit
- Twist handpiece to closed position
- Twist support tube to lock down
- Press foot pedal slowly to test drill
- Attach light cord
- Attach stopcock to southmost outflow of scope
- Attach irrigation to stopcock
-
Scope condom for TF
- Cut a small hole in the top of the condom and put on base - this should go to about 1 inch past connection for the black cord
- White balance camera (Hold W) and make sure zoom is good, check quality
- Make sure laser on field with towel over cord
- Last special clamp on Mayo
- C-arm shower cap
-
If retractor: put on retractor clamp onto clamp on bed
- Arm of retractor should have flat face facing out
- Angle second arm 45 degrees